When installing or replacing a 24V smart controller on a North American air-source or geothermal heat pump, few things trigger callback calls faster than a misconfigured heat pump o/b reversing valve. Unlike a straight-cool condenser paired with a furnace, a heat pump uses a reversing valve to flip refrigerant flow direction between heating and cooling—and HVAC brands do not follow a single universal standard for which mode energizes the valve coil.
Understanding the thermostat o vs b terminal logic is essential whenever you encounter a heat pump blowing hot air in cool mode (or blowing cool air when heat is called). Below is a practical field troubleshooting and configuration guide for contractors, distributors, and OEM integrators working with our CH7100 and CH7600 24V heat pump thermostats.
1. O vs. B Reversing Valve Logic Across Major North American Brands
In a heat pump system, the reversing valve shifts refrigerant flow direction between cooling and heating modes. Across North American HVAC equipment, two conventions are widely used:
- O Energized in Cooling: Common across brands such as Carrier, Trane, Lennox, and Goodman. The reversing valve is typically energized when cooling is active and de-energized in heating.
- B Energized in Heating: Common on Rheem and Ruud equipment (as well as certain other models), where the reversing valve is energized during heating calls rather than cooling.
| Reversing Valve Setting | Cooling Mode Output | Heating Mode Output |
|---|---|---|
| O – Energized in Cooling | 24VAC ON | 0VAC OFF |
| B – Energized in Heating | 0VAC OFF | 24VAC ON |
Note: While these configurations are common across major HVAC brands, always verify the reversing valve sequence using the wiring diagram for the exact outdoor unit model. Terminal conventions and control sequences may vary by equipment series.
2. Field Troubleshooting: Heat Pump Blowing Hot Air in Cool Mode
Always isolate power before handling wiring connections. Live 24VAC measurements should only be performed by qualified HVAC technicians using appropriate electrical safety procedures.
When a system delivers warm air during a cooling call—or cool air during a heating call—check the following four areas systematically:
- Verify O/B Reversing Valve Configuration: Confirm whether the thermostat's O/B setting matches the outdoor unit's cooling-energized (O) or heating-energized (B) behavior. An inverted setting is a frequent cause of reversed airflow after thermostat replacement.
- Check AUX / W2 / Emergency Heat & Air Handler Signals: Check whether an unexpected AUX/W2 or Emergency Heat call is present, verify whether the thermostat is actually commanding cooling or auxiliary heating, check whether W/AUX and E terminals are wired according to the equipment diagram, and confirm whether the indoor air handler is receiving an unintended heating signal. Note that during normal heat pump heating, AUX heat can operate alongside compressor heating and does not by itself indicate a wiring fault.
- Perform 24VAC Voltage Checks Referenced to C (Common): During a cooling call (for O logic) or heating call (for B logic), measure 24VAC on the O/B signal referenced to the
C(Common) wire, and verify both the thermostat output terminal and the corresponding input at the outdoor/indoor unit per the equipment schematic. - Inspect Reversing Valve Actuation & System Conditions: If the expected 24VAC signal is present in the corresponding mode but airflow direction still does not shift, inspect the reversing valve solenoid connection/coil, mechanical valve operation, and system operating conditions according to the manufacturer's service manual.
3. Configuring O/B Settings on CH7100 and CH7600 Thermostats
Both the CH7100 (4.3-inch color touchscreen) and the CH7600 (color touchscreen model) are designed for 24V multi-stage heat pump and HVAC applications up to 3H/2C, with terminal support covering O/B along with multi-stage heating/cooling and auxiliary/emergency heat terminals per each model's wiring specification, while optional protocol variants (such as Wi-Fi, Zigbee, Modbus, or BACnet) depend on the specific configuration ordered.
During installation, select the O/B operating logic in the thermostat's installer/configuration settings to match the specific heat pump model's wiring diagram, and verify actual supply airflow temperature after commissioning. Refer to the product manual or confirm exact menu options and parameter details with our engineering team when customizing builds.

4. Why Configurable O/B Matters for HVAC Contractors & OEM Brands
In North American field service and distribution, supporting selectable O/B behavior on a 24V heat pump thermostat helps contractors cover multiple equipment brands with fewer SKUs on service trucks and warehouse shelves, reducing mis-ordered parts and callback time.
For OEM and ODM buyers, configuring default O/B behavior, installer settings, and branded interfaces to match target regional HVAC systems helps reduce installation mistakes across distributor networks. Explore our Heat Pump Thermostat category or browse more technical resources in the Knowledge Centre.
Frequently Asked Questions (FAQ)
Q1: Why does my heat pump blow hot air when set to Cool?
A: Reversed O/B reversing valve logic in the thermostat configuration is a common cause after thermostat replacement. Other possibilities include unintended AUX/W2 or Emergency Heat activation, mislabeled wiring, or a reversing valve/coil issue—always verify against the equipment wiring diagram.
Q2: How do I know whether my heat pump uses O or B reversing valve logic?
A: Check the outdoor heat pump unit's wiring diagram or installation manual for the reversing valve terminal designation and energization state. Many brands (such as Carrier, Trane, Lennox, and Goodman) commonly use O energized in cooling, while Rheem and Ruud commonly use B energized in heating, though specific models can vary.
Q3: Should the O/B terminal be energized in heating or cooling mode?
A: It depends on the heat pump design: O-type systems typically energize the reversing valve during cooling, whereas B-type systems energize it during heating. Always follow the exact equipment schematic rather than guessing.
Q4: Can I use one thermostat for both Carrier and Rheem heat pumps?
A: Yes, provided the thermostat is a 24V multi-stage heat pump controller supporting both O and B reversing valve logic and matches the system's stage and power requirements. You configure the active O/B setting during commissioning to match each unit.
Q5: Can an OEM thermostat manufacturer customize O/B default settings?
A: Yes. E-TOP Controls provides OEM and ODM customization for B2B partners, including tailored firmware defaults, UI/branding options, and protocol configurations subject to project specifications and order requirements.